For several years, CHANGXIN have specialized in trading high-quality components in the field of industrial automation.
Focusing on PLC components, DCS and CNC technology, and drivetechnology
ICS TRIPLEX T8480C Trusted ® TMR analog output module T8480
40 Triple Modular Redundant (TMR) output channels per Module.
Comprehensive, automatic diagnostics and self-test.
Automatic line monitoring per point to detect open circuit and shortcircuit field wiring and load faults.
2500V impulse withstand opto/galvanic isolation barrier.
Automatic overcurrent protection (per channel), no external fusesrequired.• Onboard Sequence of Events (SOE) reporting with 1 ms resolution.
Module can be hot-replaced online using dedicated Companion(adjacent) Slot or SmartSlot (one spare slot for many Modules)configurations.
Front Panel output status light-emitting diodes (LEDs) for each pointindicate output status and field wiring faults.
Front Panel Module status LEDs indicate Module health andoperational mode (Active, Standby, Educated).TϋV Certified for non-interfering applications, refer to the safetymanual T8094.
Outputs are powered in isolated groups of eight. Each such group is aPower Group (PG).
The Trusted® TMR Analog Output Module interfaces to 40 field devices.Triplicated diagnostic tests are performed throughout the Module includingmeasurements for current, and voltage on each portion of the voted outputchannel. Tests are also performed for stuck on and stuck off failures. Faulttolerance is achieved through a Triple Modular Redundant (TMR) architecturewithin the Module for each of the 40 output channels.Automatic line-monitoring of the field device is provided. This feature enablesthe Module to detect both open and short circuit failures in field wiring andload devices.The Module provides onboard Sequence of Events (SOE) reporting with aresolution of 1 ms. An output change of state triggers an SOE entry. Voltageand current measurements onboard the Module automatically determine theoutput states.This Module is not approved for direct connection to hazardous areas andshould be used in conjunction with Intrinsic Safety Barrier devices.
ICS TRIPLEX T8480C Trusted ® TMR analog output module T8480
The TMR 4-20 mA Analog Output Module is a member of the Trusted range ofinput/output (I/O) Modules. All Trusted I/O Modules share commonfunctionality and form. At the most general level, all I/O Modules interface tothe Inter-Module Bus (IMB) which provides power and allows communicationwith the TMR Processor. In addition, all Modules have a field interface that isused to connect to Module-specific signals in the field. All Modules are TripleModular Redundant (TMR).The Field Termination Unit (FTU) is the section of the I/O Module thatconnects all three Field Interface Units (FIUs) to a single field interface. TheFTU provides the Group Fail Safe Switches and passive components necessaryfor signal conditioning, overvoltage protection, and EMI/RFI filtering. Wheninstalled in a Trusted Controller or Expander Chassis, the FTU field connectorinterconnects to the Field I/O Cable Assembly attached at the rear of theChassis.The SmartSlot link is passed from the HIU to the field connections via theFTU. These signals go directly to the field connector and maintain isolationfrom the I/O signals on the FTU. The SmartSlot link is the intelligentconnection between Active and Standby Modules for coordination duringModule replacement.
ICS TRIPLEX T8480C Trusted ® TMR analog output module T8480
Contact us:
contacts:Ella
Email:lanlan@szcxdcs.com
Email: 2259678687 @qq.com
+Skype / Whatsapp:+86-15359298293
QQ:2259678687
The Company:Spare parts module of PLC and DCS system
Allen Bradley (American AB) series products
(Modicon Electric) Series Products
General electric series products
Westinghouse Series Products
Sales of ABB Robots FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots
estinghouse: spare parts for OVATION system, WDPF system and MAX1000 system.
Invensys Foxboro: IA Series system, FBM (field I/O module) sequence control, ladder logic control, accident recall processing, digital analog conversion, I/O signal processing, data communication and processing, etc. Invensys Triconex redundant fault tolerant control system, modern fault-tolerant controller based on triple module redundancy (TMR) structure.
Bosch Rexroth: Indramat, IO module, PLC controller, drive module, etc.
Motorola: MVME 162, MVME 167, MVME1772, MVME177 and other series.
particle libraries are column numbers:
ICS TRIPLEX T8461C |
ICS TRIPLEX T8480C |
EMERSON A6370D |
GE IS220PDOAH1A 336A4940CSP2 |
ABB UFC762AE101 3BHE006412R0101 |
ABB XVC768115 3BHB007211R115 |
BENTLY 1900/65A-00-00-01-00-00 |
ABB AI895 3BSC690089R1 |
ABB TU890 3BSC690075R1 |
ABB TB852 3BSC950263R1 |
BENTLY 1900/65A-00-00-01-00-00 |
BENTLY 3500/15 127610-01 |
ABB CI627A 3BSE017457R1 |
ABB AO2000 LS25 |
BENTLY 125680-01 |
ABB S-073N 3BHB009884R0021 |
ABB 3BHL000986P0006 |
ABB 5SDF1045H0002 |
ABB 5SDF0860H0003 |
ABB 5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101 |
BENTLY 3500/40M 176449-01 |
BENTLY 3500/92 136180-01 |
ICS TRIPLEX T8480C Trusted ® TMR analog output module T8480